Overview

Inhance Suite includes:

Inhance Inflow IR 2.0, a non-contrast-enhanced MR angiography technique that has been developed to image arteries with ability to suppress static background tissue and venous flow. This sequence is based on 3D FIESTA, which provides excellent signal-to-noise ratio (SNR) and produces bright blood images. Selective inversion pulses are applied over the region of interest to invert arterial, venous, and static tissue. At the null point of the background tissue, an excitation pulse is applied to generate signal. The net result is an angiographic image with excellent background suppression and free of venous contamination. Uniform fat suppression is achieved by using a spectrally selective chemical saturation (SPECIAL) technique, while respiratory gating compatibility reduces respiratory motion artifacts during free-breathing renal exams.

Inhance 3D Velocity, designed to acquire angiographic images in brain and renal arteries with excellent background suppression in a short scan time. By combining a volumetric 3D phase contrast acquisition with parallel imaging, efficient k-space sampling, and pulse sequence optimization, Inhance 3D Velocity is capable of obtaining the whole neurovascular anatomy in approximately five to six minutes. Furthermore, background suppression is improved by the optimized pulse sequence design, resulting in better visualization of small distal vessels. Respiratory triggering is also compatible with Inhance 3D Velocity to enable abdominal angiography, specifically renal arteries. The results are excellent productivity and image quality.

Inhance 3D Deltaflow, a 3D, non-contrast-enhanced MRA application for peripheral arterial imaging. It is based on cardiac-gated, 3D, fast-spin echo and acquires two echoes, one in diastole and the other in systole. Slow arterial flow during diastole results in bright arteries in the diastole images, while faster arterial flow during systole results in dark arteries in the systole images. A subtraction of the systole images from diastole images provides arterial-only images with excellent suppression of venous and background signal. Interleaved acquisition and parallel imaging (ASSET) with optimized k-space trajectory helps reduce motion misregistration and improve vessel visualization respectively. In addition, the use of partial Fourier and coronal plane acquisition allows for considerably reduced scan time.

Inhance 2D Inflow, a pulse sequence designed to acquire angiographic images of arteries that follow almost a straight path (i.e. femoral, popliteal, and carotid arteries). Arterial blood flow is faster during the systolic phase and slows down during the diastolic phase. Therefore, Inhance 2D Inflow is designed to acquire data during the systolic phase. It features an optimized spatial saturation gap to improve fat suppression and background suppression. Peripheral Gating is deployed to minimize the pulsatile artifacts. Inhance 2D Inflow is compatible with ASSET acceleration to reduce scan time

"Inhance Inflow IR provides exquisite images of renal vasculature, reliably showing even more distal, small accessory vessels that are not possible to see with CE MRA. This is the MRA technique we have been waiting for."

Robert Lookstein, MD
Associate Professor Interventional Radiology and Cardiovascular Imaging
Mount Sinai Medical Center, New York, NY

Clinical/Economic Papers

Understand how Inhance Inflow helps you acquire consistent, reproducible images of the renal arteries. 
Download Non-Contrast Enhanced Renal MRA (PDF).

Read how technological advancement help you identify acute kidney injury in high-risk patients.
Download Identifying Acute Kidney Injury (PDF).

Learn how Inhance Inflow utilizes the in-flow effect to image arterial flow. 
Download Non-Contrast MRA in the Abdomen (PDF).

Read how our pulse-sequence technology allows you to image vasculature without using a contrast agent. 
Download Robust NCE Techniques (PDF).

See how Inhance DeltaFlow can provide you with quality visualization of peripheral arteries.
Download 3D NCE-MRA of the Peripheral Vasculature (PDF).

Clinical Image Gallery

Try It Now

Try Inhance 2.0 now!

Have your system ID ready, then click on your MR platform to begin your software download. You'll have 30 days to try it for free. Like it? Buy it. Not for you? We'll deactivate it.

Discovery* MR750 3.0T

Discovery*MR 750w 3.0T

Discovery* MR450 1.5T

Optima* MR450w 1.5T

Signa* HDxt 1.5T

Signa* HDxt 3.0T

Signa* VIBRANT 1.5T

Note: System software level 16.0 or higher is required for Signa HDxt and VIBRANT. For upgrade options, contact your sales representative directly or fill out a contact form. 


Related

SIGNA Pulse of MR

SIGNA Pulse of MR is published semi-annually by GE Healthcare and is designed to bring you the latest in MR news, clinical value, technical innovation and industry issues.

Don't miss another issue of SIGNA Pulse of MR!

  • View the latest issue or browse archived issues on our SIGNA Pulse of MR page.
  • Sign up for a complimentary subscription to SIGNA Pulse of MR! 
  • Go Digital! Download the free SIGNA Pulse of MR App at either the Apple Store or Android Market or www.amazon.com.  Now available as an application at no cost for either your Apple iPad or iPhone, Android mobile devices, or on your Kindle, the digital version of SIGNA Pulse of MR allows you to browse the latest news articles or look back through archived issues with the touch of a button.